LEM CAS Board Mount Current Transducers are designed for accurate electronic measurement of DC, AC, and pulsed currents, ranging from 1.5A RMS to 75A RMS, with galvanic isolation between the primary and secondary circuits. These Fluxgate-based transducers operate on a single +5V supply, ensuring low offset and gain drift. With a measuring range extending up to three times the nominal primary current (Ipn), the transducers offer high precision and reliability for various applications. Additionally, the LEM CAS sensors are designed for PCB mounting, making them easy to integrate into electronic systems.

Rezultāti: 6
Atlasīt Attēls Detaļas Nr. Raž. Apraksts Datu lapa Pieejamība Cenas noteikšana (EUR) Atlasiet rezultātus tabulā pēc vienības cenas, pamatojoties uz daudzumu. Daudz. RoHS ECAD modelis Strāvas parametri Sensora tips Reakcijas laiks Precizitāte Frekvenču diapazons Darba barošanas spriegums Izvades tips
LEM Uz plates uzstādāmi strāvas sensori Current Transducer CAS series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic seperation between the primary and the secondary circuit. 286Ir noliktavā
200Paredzamais 24.04.2026
Min.: 1
Vair.: 1

15 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Uz plates uzstādāmi strāvas sensori Current Transducer CAS series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic seperation between the primary and the secondary circuit. 443Ir noliktavā
200Paredzamais 24.03.2026
Min.: 1
Vair.: 1

25 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Uz plates uzstādāmi strāvas sensori Current Transducer CAS series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic seperation between the primary and the secondary circuit. 165Ir noliktavā
Min.: 1
Vair.: 1

50 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Uz plates uzstādāmi strāvas sensori Current Transducer CAS series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic seperation between the primary and the secondary circuit. 598Ir noliktavā
Min.: 1
Vair.: 1

6 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Uz plates uzstādāmi strāvas sensori Noliktavā neesošas preces izpildes laiks 14 Nedēļas
Min.: 200
Vair.: 200
15 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Uz plates uzstādāmi strāvas sensori Noliktavā neesošas preces izpildes laiks 14 Nedēļas
Min.: 200
Vair.: 200
25 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog